IEC61215, IEC61730
TUV, CE
ISO 9001:2015
ISO 14001:2015
ISO 45001:2018
25-year linear power output guarantee
The power attenuation of single crystal modules shall not exceed 2% in the first year,
and the power attenuation shall not exceed 0.55% every year thereafter,
and the module power at the end of the 25-year guarantee period shall not be lower than 84.8% of the nominal power;
*The above power test is carried out under standard test conditions
| Maximum output power (W)0-+5W | Maximum working voltage (V) | Maximum working current (A) | Open circuit voltage (V)±3% | Short circuit current (A)±3% | Conversion efficiency | system voltage | Maximum Fuse Rating |
| 580 | 33.62 | 17.25 | 40.72 | 18.28 | 20.49% | 1500V | 30A |
| 585 | 33.82 | 17.30 | 40.92 | 18.36 | 20.67% | 1500V | 30A |
| 590 | 34.03 | 17.34 | 41.13 | 18.41 | 20.85% | 1500V | 30A |
| 595 | 34.22 | 17.39 | 41.32 | 18.46 | 21.02% | 1500V | 30A |
| 600 | 34.43 | 17.43 | 41.52 | 18.51 | 21.20% | 1500V | 30A |
range of working temperature: | -40℃~+85℃ |
Nominal operating temperature: | 45±2℃ |
Short-circuit current temperature coefficient: | 0.048%/℃ |
Open circuit voltage temperature coefficient: | -0.252%/℃ |
Maximum output power temperature coefficient: | -0.332%/℃ |
Component Dimensions: | 2172×1303×35mm |
Component weight: | 31kg±3% |
Snow load/wind load: | 5400/2400 Pa |
Number of cells: | 120pcs |
glass thickness: | 3.2mm |
Junction Box: | IP68, 3 diodes |
Line length: | Positive pole 250mm/negative pole 300mm (including connector) |
Connector: | HTC-16, IP68 |
12 years of technical process, material quality assurance
25-year linear power output guarantee
Quantity of components per tray: | 31pcs |
Quantity of components per 40-foot high cabinet: | 527 pcs |
|
The company reserves the right of final interpretation.








Irradiance 1000W/㎡
Temperature 25°C
AM=1.5
Wind speed 1m/s